SPRINKLER-PAC™ with Integrated Nitrogen

SPRINKLER-PAC™ with Integrated Nitrogen is a fully assembled dry-pipe sprinkler valve fire suppression system, including dry-pipe valve, trim, and nitrogen generator providing one complete zone of dry-pipe water sprinkler fire protection.

To learn more about the SPRINKLER-PAC™ fire suppression assembly, give us a call at 908.688.0300 or contact us online.

About SPRINKLER-PAC™

All components are contained in three (3) red powder-coated steel enclosures. Dry-pipe and nitrogen system indicators and controls are mounted facing forward for easy reference and use. The connections allowing monitoring of waterflow, tamper, and low / high air signaling switches are behind the electrical enclosure door. Lockable latches on enclosure doors permit restricted access to connections and components. Gasketing provides sealing of the enclosure doors. Knockouts permit easy attachment of external electrical raceways.

SPRINKLER-PAC™ Features

  • Fully factory assembled and tested
  • No field assembly required
  • Just connect water supply, drain, and sprinkler piping
  • Attractive and rugged metal enclosure
  • Easy-to-see gauges on enclosure front
  • Separate, lockable valve, electrical, and nitrogen enclosures
  • Space for required spare sprinkler heads and wrench
  • UL / FM / NYC approved major components
  • 1-1/2 inch through 6 inch valve options

SPRINKLER-PAC™ Benefits

  • Saves assembly and installation time
  • Quicker commissioning – just place, connect, and it’s ready
  • Finished appearance allows placement in or near hazard
  • Reliable, dependable protection that functions as designed
  • Easy inspection and maintenance
  • Expert in-house and field technical support

 


Contact UNITED Fire Systems Today

Give us a call at 908.688.0300 or contact us online to request more information about the SPRINKLER-PAC™ system. 


Resources


Data Sheets +-


Info Sheets +-

Need help figuring out what you need?
See our PREACTION-PAC™ AND SPRINKLER-PAC™ SELECTION GUIDE.


Certifications And Approvals +-

Did You Know?
  • Your dry-pipe or preaction fire sprinkler system can be infected! That’s right – microbes can be lurking inside your sprinkler pipes and causing damage.  Microbiologically influenced corrosion (MIC) occurs when the right combination of moisture and microbial organisms produces rapid corrosion of steel piping from the inside out. MIC is not the only cause of steel pipe corrosion, but it is important to know about and mitigate this problem BEFORE it causes pitting, pinholes, and thinning of pipe walls. Take steps to prevent both rust and MIC by using NITROGEN-PAC.