908.688.0300

NITROGEN-PAC™ Models SC-1 and SC-2

 

The NITROGEN-PAC™ SC (Self-Contained) Series is a family of FM Approved nitrogen-based sprinkler corrosion inhibiting systems, providing high-purity dry nitrogen for the interior of preaction and dry sprinkler piping. These units feature an air compressor for system fast-fill and nitrogen generation, refrigerated drying of the air for the lowest possible moisture content, and membrane technology for nitrogen generator efficiency. The NITROGEN-PAC™ SC Series factory-assembled units save space and shorten installation and commissioning time.

Give us a call at 908.688.0300 or contact us online to learn more!

NITROGEN-PAC™ SC Series Features & Benefits:

  • FM Approved
  • Fully factory assembled, adjusted, and tested
  • No field assembly required
  • Just attach AC power and run piping to sprinkler riser
  • Built-in UL Listed oilless air compressor
  • UL Listed refrigerated dryer delivers -40°F dew point air
  • Membrane-based nitrogen generator
  • Built-in particulate and coalescing filters
  • Single or multiple riser capable
  • 22 gallon nitrogen receiver
  • Digital compressor runtime monitor
  • Visual indicators of system status
  • Leveling feet
  • Rugged steel construction
  • Saves installation, assembly, and testing time
  • Smallest footprint complete nitrogen system available today
  • Quicker commissioning—just place, connect, and it’s ready
  • Nitrogen generation and sprinkler fast-fill (per NFPA 13) from just one unit
  • Our True Advanced Purge (TAP) can be used with the NITROGEN-PAC™ SC!

Give us a call at 908.688.0300 or contact us online to learn more about the NITROGEN-PAC™ SC Series.


Resources


Data Sheets +-


Engineering Specifications & Drawings +-

For .DWG and .DOC versions of these documents, download our Specification Developer


Manuals +-


Instruction Sheets +-


Commissioning & Maintenance Checklists +-


Sales Literature +-


Info Sheets +-

Need help figuring out what you need?
See our NITROGEN-PAC™ EQUIPMENT SELECTION GUIDE.


Technical Notes & Important Info +-


Certifications And Approvals +-


Warranty Information +-

Did You Know?
  • Your dry-pipe or preaction fire sprinkler system can be infected! That’s right – microbes can be lurking inside your sprinkler pipes and causing damage.  Microbiologically influenced corrosion (MIC) occurs when the right combination of moisture and microbial organisms produces rapid corrosion of steel piping from the inside out. MIC is not the only cause of steel pipe corrosion, but it is important to know about and mitigate this problem BEFORE it causes pitting, pinholes, and thinning of pipe walls. Take steps to prevent both rust and MIC by using NITROGEN-PAC.